Industry field guide
Connector mating data for training and evaluating AI
A connector that looks seated can still have a partly engaged latch.
- Sector
- Manufacturing
- 2022 NAICS
- 334417
- Practice pack
- Example and answer key (JSON)
- Updated
What this guide tests
How should C4 be scored on the two checks?
See the specimen and fields · Work through the fictional records
Task and source context
A connector that looks seated can still have a partly engaged latch. NIST’s robotic assembly test methods include connector insertions. A connector manufacturer can build an evaluation around the last visible clue before a confirmed seat, then test how well that clue transfers to a different housing. NIST assembly performance metrics
Use a de-energized practice pair. Record the keyed approach, an approved incomplete-seat demonstration, and the verified seated state. Add a macro view or authorized measurement from the same attempt. The labels can identify compatible part pair, orientation, apparent versus measured seat, and whether the latch was observable. Put a different housing family in a holdout set so the test does not reward recognition of one connector shape.
Use an owned demo, anonymous dimensions where acceptable, and consented hands-only recording. Avoid sharing customer pinouts, unreleased housing drawings, and test results tied to a restricted assembly.
Industry research
The U.S. Census Bureau’s industry definitions establish which activities these codes cover. The workflow sources in this guide describe the task or record type. Fiund’s pilot below uses fictional material to test a specific decision within that scope.
334417 · Electronic Connector Manufacturing
This U.S. industry comprises establishments primarily engaged in manufacturing electronic connectors, such as coaxial, cylindrical, rack and panel, pin and sleeve, printed circuit, and fiber optic.
Build a pilot sample
Set up this pilot
Use inert connector props with aligned marks but unequal gaps. Take one photo off the reference plane and grade alignment separately from the calibrated seat observation.
Label the top and side images with the same fixture ID. Give the side image a readable scale at the mating plane and record the observed gap before applying the exercise threshold. Include a correctly oriented connector with a deliberately excessive gap, then reverse which criterion fails in a second packet. A single pass/fail label would conceal the difference.
Prepare the test packets
- Start with the worked case. Use the fictional record types below as a guide to the source files you need. Give each packet a stable ID and save its source versions with it.
- Change one fact. Make one packet with enough evidence to answer the question and one where the evidence points to a different answer. Keep the other fields fixed so a reviewer can tell what changed.
- Remove the decisive evidence. Give the reviewer a third packet with a plausible near-match in its place. Have them write what can still be established and what evidence would resolve the rest.
Fields the reviewer needs
- notch_alignment
- Checks orientation independently
- seating_gap_mm
- Quantifies the observed fit dimension
- reference_plane
- Makes measurements comparable
Use What machinery and electronics manufacturers can contribute to AI to turn the specimen into a brief with a defined task, source and review owner.
Fictional exercise
Orientation can be correct while seating remains incomplete
Two paper housings have identical profiles and a visible reference notch. Mock gap readings are provided.
| Record ID | Source | What it records |
|---|---|---|
| 1 | Drawing | Expected notch alignment; seated toy gap at most 1 mm. |
| 2 | Photo | Notches line up in sample C4. |
| 3 | Gap table | C4 gap measured 3 mm from the stated reference plane. |
Question for the model. How should C4 be scored on the two checks?
Show the reference answer
C4 matches the orientation criterion in records 1 and 2, but its 3 mm reading exceeds the toy seating limit by 2 mm under records 1 and 3. Store separate orientation and gap results rather than using notch alignment as proof of seating.
How to check the result
Ask for the answer, the record IDs that support it and any fact the evidence leaves unresolved. Have a reviewer compare the response against the reference before deciding whether the sample is ready to expand.
Errors to flag in this case
- Treating alignment as completion
- Comparing a gap without its reference plane
Change the inputs and run it again
Use a photo that conceals the mating plane while notches remain visible; retain alignment and abstain on seating.
Score the decision and the evidence separately
Save the reviewer’s expected answer, supporting record IDs and unresolved fields in a separate answer key. Score the model on the decision, its citations and its handling of the deliberate gap. A correct answer citing a different case counts as an evidence error.
Before expanding collection, have a second reviewer run the same checks on the held-out packet. Keep related versions, views and exports of the same case together so they stay on one side of the training and evaluation split.
Check permission and scope
No actual connectors, pinouts, installation, electrical compatibility or genuine tolerances.
Leave out real circuit layouts, patient data, customer captures, credentials and protected equipment settings.
Describe an authorized archive through Fiund’s existing-data assessment, or describe a new capture capability through the collection brief. The contributor agreement covers the terms for participation.
Sources and further reading
Resources for this workflow
Includes worksheet
What machinery and electronics manufacturers can contribute to AI
Match an equipment or electronics dataset to a configuration and checkable task.
Includes worksheet
Manufacturing AI sample worksheet: visible state and matching evidence
Build a specimen around a marked unit and independently checked observation.
Company and program reviews
Use these reviews to compare sourcing, capture or evaluation approaches. Confirm the applicable program, accepted sources and terms with the provider.
Compare the approach
Dexset review: robotics capture, samples and acceptance
Compare multiple views, labels and what an export actually preserves for assembly tasks.
Compare the approach
Sama review for computer-vision labeling and model evaluation
Compare review criteria for hard-to-see state changes, occlusion and ambiguous labels.
Related industry examples
Industry guide · NAICS 334418
Circuit board assembly rework data for AI inspection
An assembly inspection photo can show the right board and the wrong moment.
Industry guide · NAICS 334416
Passive electronic component data for AI value and condition checks
NIST's SI guidance provides context for units and prefixes.
Industry guide · NAICS 334412
Bare printed circuit board inspection data for AI
A bare board inspection model needs to tell a real indication from an alignment error.