Industry field guide
Wheat moisture and sample records for AI checks
A wheat ticket may refer to a truckload while a meter result refers to one compartment.
- 2022 NAICS
- 111140
- Practice pack
- Example and answer key (JSON)
- Updated
What this guide tests
Which compartment has a matched day-2 result, and can the packet support B's current value or a shipment-wide average?
See the specimen and fields · Work through the fictional records
Task and source context
A wheat ticket may refer to a truckload while a meter result refers to one compartment. If an assistant treats those IDs as equivalent, it can attribute the same moisture reading to grain it has never seen. USDA’s Federal Grain Inspection Service publishes a grading handbook and laboratory reference methods. These give context for designing a record-matching evaluation. USDA FGIS handbooks · USDA reference methods
Create two fictional compartments with separate sample numbers and one combined shipment record. Record the device, the units, and the time for a result on the first sample. Attach a differently dated reading to the second. The expected answer should cite which sample each result actually describes and identify the gap before attempting a comparison. Ask the buyer whether the test needs a document, an image of the meter, or both.
Remove buyer names, locations, elevator contracts, and pricing. Verify the right to use any instrument export and certificate. An internal grain specialist can approve a recreated exercise without copying commercial records.
Industry research
The U.S. Census Bureau’s industry definitions establish which activities these codes cover. The workflow sources in this guide describe the task or record type. Fiund’s pilot below uses fictional material to test a specific decision within that scope.
111140 · Wheat Farming
This industry comprises establishments primarily engaged in growing wheat and/or producing wheat seeds.
Build a pilot sample
Set up this pilot
Use dummy wheat compartments with different sample dates and moisture records. Match the current requested compartment and grade whether weighting evidence supports any shipment average.
Prepare the test packets
- Start with the worked case. Use the fictional record types below as a guide to the source files you need. Give each packet a stable ID and save its source versions with it.
- Change one fact. Make one packet with enough evidence to answer the question and one where the evidence points to a different answer. Keep the other fields fixed so a reviewer can tell what changed.
- Remove the decisive evidence. Give the reviewer a third packet with a plausible near-match in its place. Have them write what can still be established and what evidence would resolve the rest.
Fields the reviewer needs
- Shipment, compartment and sample
- Defines nested source scope.
- Measurement date, device and unit
- Supports the specific observation.
- Sample equivalence and weight basis
- Identifies gaps before comparison or aggregation.
Use Plan a farm, forest or fishery AI data sample to turn the specimen into a brief with a defined task, source and review owner.
Fictional exercise
One compartment's moisture reading does not characterize an entire shipment
Two fictitious compartments have original grain tickets and arbitrary practice readings. No elevator contract, pricing, actual certificate or storage recommendation is represented.
| Record ID | Source | What it records |
|---|---|---|
| WM1 | Shipment map | Shipment H combines compartments A and B. A sampled as S-A on day 2; B sampled as S-B on day 2. |
| WM2 | Matched meter record | S-A, day 2, device D, moisture 12 practice percent. Exact sample reference and unit supplied. |
| WM3 | Attached second reading | S-B-old, day 1, device D, 14 percent. No S-B-old-to-S-B equivalence or matching day-2 B reading supplied. |
Question for the model. Which compartment has a matched day-2 result, and can the packet support B's current value or a shipment-wide average?
Show the reference answer
WM1 and WM2 match the 12-percent reading to A's day-2 sample S-A. WM3 concerns an older, differently identified B-like sample and supplies no verified day-2 S-B result. B's current value remains unresolved, and no component-weight basis supports a shipment-wide average. Preserve compartment and sample identity rather than extend A's reading to all of H or treat the older attachment as an interchangeable current sample.
How to check the result
Ask for the answer, the record IDs that support it and any fact the evidence leaves unresolved. Have a reviewer compare the response against the reference before deciding whether the sample is ready to expand.
Errors to flag in this case
- Applying one compartment's measurement to the combined shipment.
- Treating a similar sample ID from another date as a current result or averaging without component weights.
Change the inputs and run it again
Supply B's matching day-2 result but omit component masses. Require both local values to resolve while a mass-weighted shipment average remains unsupported.
Score the decision and the evidence separately
Save the reviewer’s expected answer, supporting record IDs and unresolved fields in a separate answer key. Score the model on the decision, its citations and its handling of the deliberate gap. A correct answer citing a different case counts as an evidence error.
Before expanding collection, have a second reviewer run the same checks on the held-out packet. Keep related versions, views and exports of the same case together so they stay on one side of the training and evaluation split.
Check permission and scope
Use recreated tickets reviewed by a grain specialist. Exclude buyers, locations and commercial terms; verify instrument-export and certificate rights separately.
Remove precise farm coordinates and operator identifiers from a review copy. Keep the linkage between lot, sample and outcome intact.
Describe an authorized archive through Fiund’s existing-data assessment, or describe a new capture capability through the collection brief. The contributor agreement covers the terms for participation.
Sources and further reading
Resources for this workflow
Company and program reviews
Use these reviews to compare sourcing, capture or evaluation approaches. Confirm the applicable program, accepted sources and terms with the provider.
Compare the approach
truelabel review for teams collecting physical AI data
Compare how a capture team specifies devices, processing and quality review for an outdoor recording pilot.
Compare the approach
Graviti review for workplace video and multimodal training data
Compare a catalog with commissioned multimodal collection when a particular crop, setting or viewpoint matters.
Related industry examples
Industry guide · NAICS 111150
Corn and sorghum yield-monitor data for AI evaluation
A colored yield map can hide the difference between a low-yield strip and a change in sensor calibration.
Industry guide · NAICS 111110
Soybean and oilseed sample data for AI quality review
A picture of damaged seed can be useful.
Industry guide · NAICS 111160
Rough rice sample and milling-yield data for AI review