Skip to content

Industry field guide

Structural steel and precast member identity data for AI

A drawing and an installed member may have similar marks for different locations.

2022 NAICS
238120
Updated

What this guide tests

Which member-to-location association is visibly supported under revision B, and what remains unresolved for the panel?

See the specimen and fields · Work through the fictional records

Task and source context

A drawing and an installed member may have similar marks for different locations. OSHA’s steel erection materials provide context for this work. An offline exercise can test identity and observation without asking a model to direct installation. OSHA steel erection site preparation

Use tabletop props and a simplified plan. Give a fictional beam and a panel separate marks, then change one location in a revision. Use two views of each prop. Ask which observations support each member’s recorded location and whether the obscured mark needs another view. A reviewer should score identification independently of any engineering judgment.

Do not record lifting, connection work, active equipment, site details, client plans, or identifiable workers. Use approved inert props and original documents.

Describe a tabletop member identification sample

Industry research

The U.S. Census Bureau’s industry definitions establish which activities these codes cover. The workflow sources in this guide describe the task or record type. Fiund’s pilot below uses fictional material to test a specific decision within that scope.

238120 · Structural Steel and Precast Concrete Contractors

This industry comprises establishments primarily engaged in (1) erecting and assembling structural parts made from steel or precast concrete (e.g., steel beams, structural steel components, and similar products of precast concrete) and/or (2) assembling and installing other steel construction products (e.g., steel rods, bars, rebar, mesh, and cages) to reinforce poured-in-place concrete. The work performed may include new work, additions, alterations, maintenance, and repairs.

U.S. Census Bureau, 2022 NAICS Manual, p. 129 ↗

Build a pilot sample

Set up this pilot

Draw neutral steel member marks and a revised location plan. Photograph one full mark and a cropped mark, then grade supported placement separately.

Prepare the test packets

  1. Start with the worked case. Use the fictional record types below as a guide to the source files you need. Give each packet a stable ID and save its source versions with it.
  2. Change one fact. Make one packet with enough evidence to answer the question and one where the evidence points to a different answer. Keep the other fields fixed so a reviewer can tell what changed.
  3. Remove the decisive evidence. Give the reviewer a third packet with a plausible near-match in its place. Have them write what can still be established and what evidence would resolve the rest.

Fields the reviewer needs

Full member mark and type
Distinguishes B-12 from P-12.
Revision-specific location
Preserves the localized plan change.
View and mark visibility
Separates planned placement from observed identity.

Use How construction and trade teams can contribute data for AI to turn the specimen into a brief with a defined task, source and review owner.

Fictional exercise

A changed location applies to the named member alone

A foam beam and a cardboard precast-panel prop have similar short marks. An original practice plan changes one location, and two image views differ in label visibility.

Records supplied to the evaluator
Record IDSourceWhat it records
SP1Practice plan revision ABeam B-12 assigned slot 1; panel P-12 assigned slot 2.
SP2Plan revision BB-12 moves to slot 3; P-12 remains slot 2. Revision B supersedes A for the beam location.
SP3Approved tabletop imagesView 1 shows B-12 label at slot 3. View 2 shows a panel-shaped prop at slot 2, with its P-12 mark covered.

Question for the model. Which member-to-location association is visibly supported under revision B, and what remains unresolved for the panel?

Show the reference answer

SP2 and SP3 support B-12 at its revised slot 3. The plan keeps P-12 assigned to slot 2, and an image shows a panel-shaped prop there, but the covered mark prevents direct identity confirmation. Shape and planned position do not establish the observed P-12 identifier. Preserve the panel assignment as documented and its visual identity as unresolved, without making an installation or engineering approval.

Download the fictional records and answer key (JSON)

How to check the result

Ask for the answer, the record IDs that support it and any fact the evidence leaves unresolved. Have a reviewer compare the response against the reference before deciding whether the sample is ready to expand.

Errors to flag in this case

  • Applying the beam's slot change to the panel because both marks end in 12.
  • Calling the covered panel mark verified from its expected slot and shape alone.

Change the inputs and run it again

Reveal P-13 on the slot-2 panel in a second view. Require a conflict against the P-12 assignment rather than silent relabeling of the plan.

Score the decision and the evidence separately

Save the reviewer’s expected answer, supporting record IDs and unresolved fields in a separate answer key. Score the model on the decision, its citations and its handling of the deliberate gap. A correct answer citing a different case counts as an evidence error.

Before expanding collection, have a second reviewer run the same checks on the held-out packet. Keep related versions, views and exports of the same case together so they stay on one side of the training and evaluation split.

Check permission and scope

Use approved inert tabletop props and independent documents. Do not record lifting, connections, active equipment, client plans, locations or identifiable workers.

Work with a controlled training setup or authorized records. Keep customer premises, identities and unsafe live equipment out of practice capture.

Describe an authorized archive through Fiund’s existing-data assessment, or describe a new capture capability through the collection brief. The contributor agreement covers the terms for participation.

Sources and further reading

Resources for this workflow

How the examples work

Company and program reviews

Use these reviews to compare sourcing, capture or evaluation approaches. Confirm the applicable program, accepted sources and terms with the provider.

All company reviews

Related industry examples

← Construction