Industry field guide
Biomass fuel reporting-basis records for AI
A feedstock record can report as-received mass while another uses a dry basis.
- Sector
- Utilities
- 2022 NAICS
- 221117
- Practice pack
- Example and answer key (JSON)
- Updated
What this guide tests
Which dry-basis amount is supported, and can Lot B's dry mass be calculated using the supplied fraction?
See the specimen and fields · Work through the fictional records
Task and source context
A feedstock record can report as-received mass while another uses a dry basis. A model needs units and method before comparing amounts. EIA’s renewable energy and electricity reporting material provides context for fuel records. A generator can use a fictional example to test the assistant’s unit and basis checks. EIA renewable energy context · EIA Form 923 reporting data
Make two dummy tickets and mark the reported basis for each. Supply an authorized comparison for one pair with matching units, and leave a required field blank for another. Ask which comparison is supported and what information remains missing. Distinguish the supplier’s observation from the generator’s reviewed value.
Keep actual feedstock sources, fuel recipes, plant information, commercial quantities, rates and operational records out of the sample. Do not ask the model to manage fuel or equipment.
Industry research
The U.S. Census Bureau’s industry definitions establish which activities these codes cover. The workflow sources in this guide describe the task or record type. Fiund’s pilot below uses fictional material to test a specific decision within that scope.
221117 · Biomass Electric Power Generation
This U.S. industry comprises establishments primarily engaged in operating biomass electric power generation facilities. These facilities use biomass (e.g., wood, waste, alcohol fuels) to produce electric energy. The electric energy produced in these establishments is provided to electric power transmission systems or to electric power distribution systems.
Build a pilot sample
Set up this pilot
Make a practice dry-mass calculation with a fraction linked to one lot only. Put a comparable-looking weight on the second lot and verify the missing conversion stays unresolved.
Prepare the test packets
- Start with the worked case. Use the fictional record types below as a guide to the source files you need. Give each packet a stable ID and save its source versions with it.
- Change one fact. Make one packet with enough evidence to answer the question and one where the evidence points to a different answer. Keep the other fields fixed so a reviewer can tell what changed.
- Remove the decisive evidence. Give the reviewer a third packet with a plausible near-match in its place. Have them write what can still be established and what evidence would resolve the rest.
Fields the reviewer needs
- Lot identity
- Keep the comparison method attached to the reviewed lot.
- Mass unit and basis
- Distinguish kilograms from the definition of the measured material.
- Review or conversion evidence
- Record which amount is supplied, calculated under the exercise or unresolved.
Use Plan a sample of business data for AI to turn the specimen into a brief with a defined task, source and review owner.
Fictional exercise
Compare an invented fuel ticket on its stated basis
Fictional mass records illustrate reporting-basis checks. The exercise supplies no real feedstock, recipe, commercial quantity or fuel-management instruction.
| Record ID | Source | What it records |
|---|---|---|
| LOT-A-WET | Dummy supplier ticket | Lot A reports 10 kg as received. |
| LOT-A-REVIEW | Independent practice review | For this exercise only, Lot A's documented dry-mass fraction is 0.60, producing 6 kg on the dry basis. |
| LOT-B-WET | Different-lot ticket | Lot B reports 12 kg as received. No dry-mass fraction or dry-basis review is supplied. |
Question for the model. Which dry-basis amount is supported, and can Lot B's dry mass be calculated using the supplied fraction?
Show the reference answer
Lot A has a supported 6 kg dry-basis amount under LOT-A-REVIEW. The 0.60 fraction is explicitly scoped to A. Lot B's 12 kg as-received value does not establish its dry mass, and A's fraction cannot be silently reused for B. Preserve lot, unit, basis and review method before comparing the amounts.
How to check the result
Ask for the answer, the record IDs that support it and any fact the evidence leaves unresolved. Have a reviewer compare the response against the reference before deciding whether the sample is ready to expand.
Errors to flag in this case
- Applying one lot's documented fraction to another lot without evidence.
- Comparing an as-received quantity directly with a dry-basis quantity as though they share a definition.
Change the inputs and run it again
Add a separately reviewed dry fraction for B, then change A's unit to grams. The evaluator must resolve both basis and unit before comparison.
Score the decision and the evidence separately
Save the reviewer’s expected answer, supporting record IDs and unresolved fields in a separate answer key. Score the model on the decision, its citations and its handling of the deliberate gap. A correct answer citing a different case counts as an evidence error.
Before expanding collection, have a second reviewer run the same checks on the held-out packet. Keep related versions, views and exports of the same case together so they stay on one side of the training and evaluation split.
Check permission and scope
All figures are invented. Exclude real fuel sources, plant information, recipes, rates and operational records. No equipment or fuel action is recommended.
Use a controlled simulation or an authorized export with topology, customer details and control-system information removed.
Describe an authorized archive through Fiund’s existing-data assessment, or describe a new capture capability through the collection brief. The contributor agreement covers the terms for participation.
Sources and further reading
Resources for this workflow
Company and program reviews
Use these reviews to compare sourcing, capture or evaluation approaches. Confirm the applicable program, accepted sources and terms with the provider.
Compare the approach
Scale AI review: data partnerships, Outlier and buyer services
Read how the company frames energy and utility data partnerships and what it asks of established operators.
Compare the approach
Sapien review: dataset quality review and expert checks
Compare expert quality review if a pilot needs independent checks of evidence and labels.
Related industry examples
Industry guide · NAICS 221112
Fossil generation reporting-basis data for AI review
Gross and net figures can describe the same interval while representing different quantities.
Industry guide · NAICS 221121
Bulk electric transmission aggregates for offline AI review
A revised aggregate can change a historical summary without revealing which underlying event caused the change.
Industry guide · NAICS 221116
Geothermal observation source records for AI review
A report can reuse an instrument label after its assigned sample point changes.